GMS General Management System Panels
SCHNEIDER LOCAL PANEL PARTNER - LEGRAND XL³ PANEL PARTNER - ABB LOCAL PANEL PARTNER
Schneider Prisma P EVO

yapım aşamasında...

EASY 9 FUSE BOX

Explanation

Easy 9, fuse boxes, modular DIN rail is designed for installation in the housing of the product. Easy9 fuse boxes are for indoor use. 18 mm 8, 12, 18, 24 and 36 modules are available.

With its ergonomic design allows easy installation.

180 ° can be opened up are transparent and opaque cover options.

in the fourth side are pre-cut cable holes.

3 can be DIN-rail until the wiring outside of the rear body.


Recessed fuse box:

body

depth that is adapted to the walls of lesser thickness,

4 sides of the pre-drilled holes for cable entries found,

It has a symmetrical and rigid rear body


Surface mount fuse box:

assembly having kolayalştır design,

It has a body having connection holes which allow vertical mounting.

For cable entry, there is a large area that allows you to easily perform the pre-cut holes and drilling

Quality

- 100% it designed and manufactured by Schneider Electric. - All manufacturing facilities are ISO 9000 certified. - Easy9 everywhere; apartments, houses, villas, offices, and may be preferred for use in the workplace.

- Compliance with international standards.

IP65 polyester PANELS IP65 polyester PANELS IP65 polyester PANELS

FS polyester enclosures and Features

Body, rear panel and door fittings glass fiber reinforced polyester, hot compression, RAL7032 color made with mold. last the same for all surfaces.
identified by bosses for fixing points.
Storage 4 versions:
- Fully sealed, IP 65.
- The bottom is open, and integrated Qaeda, IP54.
Ventilation, tops open to IP44.
Ventilation, IP44 - open lower and upper part of al-Qaeda and clear.
Accessories to upgrade to IP54 IP44.
500x500x320mm up 1500x1250x420mm 40 dimensions.
1 door, 500 and 750 mm wide and 2 Doors, 1000 and 1250mm width.
2 doors enclosures constructed with reinforcement central part.
or door panels to Antiflyposting 3 types: flat, grooved surfaces, glass.
handle with a lock or locks, outside the protected volume 2 or 4 action points.
Flat-impact resistance: IK10 and glazed door to door visiting, IK08 grooved.
Self extinguishibility: HB40 classified and 960º test resistant.
İEC62208 accordance with the safe certification standard.
Polyester Qaeda Z 200 mm, translation 2x200mm, PLA enclosures, sub-version off
PLA-Qaeda safe Polyester ZZ 200 mm and 500 mm, open lower versions
UL / CUL certificate (depending on the version)
- NSYPL Certified
Not Approved - NSYPLAT, NSYPLAZ and NSYPLAZT-
Parts Crates
Schneider selected a wide range of spare parts for your safe Electric. No matter how safe are newly built or a few years, you can get the parts you need.

benefits
Floor-standing polyester casing

Electrical contact risks.
Suitable for indoor or outdoor use.
resistant to harsh environments.
It is used in a wide temperature range.
Easy machinery and processing does not produce corrosion.
Halogen free.
Light provides an easy setup.
a long-lasting life without maintenance.
strong shocks.
Canopy version for outdoor use, protect the seal quality.
65 mm integrated and easy-Qaeda from the open bottom of the release of the cables.
(40 size) a wide variety of sizes.
Door selection (flat, grooved surface anti-flyposting, glass).
(Soil base on the wall) to install various possibilities.
Coupling possibilities thanks to modular sizes.
Audio output protected locking system.
Composition accessories number abroad.
Installation or use universal (question was asked, modular distribution) applications (metal or insulating material) or chassis plates.
Lock, improved depth customized service: color, machining, mounting accessories, replace it.
Instead, door panels and rear doors 3 types of combination of the 4 version.
Qaeda ZM 200 mm

protection against the rise of water access - cable management
Applications
Energy Infrastructure, energy distribution and control, industrial markets, indoor or outdoor, harsh conditions or environment installed and electricity in order to avoid risks.

MINI PRAGMA FUSE BOXES MINI PRAGMA FUSE BOXES

mini Pragma plastic modular fuse box

Product information


Recessed or surface-mounted in a plastic fuse box

Plastic modular fuse box options, surface-mounted or flush-50 to 63

1 to 3 as

4 to 36 as

Smoky transparent or white lid

Options

Flush: 5 colors (white, ivory, gray mystical, pistachio green, garnet)

Terminal block or terminal unblocked

Function «emergency lighting»

Lock

Advantages


a sigorat box can Exhibitions

complete interior decoration in the living area, a fuse box designed to comply with key outlets.

a fuse box designed to facilitate the work of an electrician.

 complete electrical installation solutions for housing.


Applications

Residential, hotel rooms, small offices:
Mini Pragma electrical system of your heart, and insurance protection designed for easy and safe installation of the control device adapts well to kutusudur.ayrı the switch socket.

PRAGMA FUSE BOXES

PRAGMA

13/18/24 module box series distribution board series

Product information
13/18/24 Pieces with a complete range of modular boxes


over handrail mounting options: metal / teknoplas
- 13 - 18 modules, 63-125 A
- 24 modules, 125 to 160 A together with the end-user interface

flush mounting option: We teknoplas
- 13 - 18 modules, 63-125 A
- 24 modules 125-160 to

Advantages


Pragma new product offerings, as well as the best seviyedeergonom for the installer also offers aesthetic and durability.

Designed to be used in combination with Schneider Electric it is the right solution literally branded products.

more is esnekliksun for more simplicity and user setup.

Applications

  Commercial and high-quality housing

GMS AG Wall Systems
Distribution Panel Distribution Panel Distribution Panel Distribution Panel Distribution Panel Distribution Panel
Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels Type Test (61439-1/2) Low Voltage Distribution and MCC Panels

Because of GMS Dashboard modular structure and broad range of products , all applications with all kinds of brand switching solution offers a fast way

 

Because of , robust, flexible and aesthetic of structures of models , the things that may occur during production or in the field it may change quickly and simple. .

 

Unlike other boards BOLTS of the most important feature of the cover plate is cross type with special hinges ,

 

Again, because of using a hinges , screwdriver and switch cover plates capable of insertion and removal quick and simple way .

 

GMS Board comb busbar isolators supports ( IEC / EN 61439-2 according to )

 

Supplied of metal surfaces as specified in section bearings , all plastic parts that may arise from the effects of electrical and fire resistant to temperature rise of 960 ° C for 30s flame retardancy test has been documented and tested .

 

 

 

General features

 

 Forming types: up to 4b .

 Icw : 85 ka/1s main bus short circuit withstand current up to ( with bars in 4000 )

 Ipk : 188 ka/3ms main bus short circuit withstand current up to ( with bars in 4000 )

 IEC 61439-1/2

 IP 20 - IK 08 cover plate without door

 IP 30 - IK 08/10 Doors Metal & Glass

 IP 31 - IK 08/10 Doors Metal & Glass

 IP 40 - IK 08/10 Doors Metal & Glass

 IP 43 - IK 08/10 Doors Metal & Glass

 IP 54 - IK 08/10 Doors Metal & Glass

 IP 55 - IK 08/10 Doors Metal & Glass

 Board Material (IEC 61439-2 ) 10.2,10.2.2

Sheet metal corrosion protected

Surface , anti- corrosion, heat- polymerized epoxy -polyester powder coating

Carcass Galvanized Frame

Plate mounting in Galvanized chassis

Door, side cover, back cover , Cover plate painted RAL7035

Sub- base and door painted RAL7035

Transfer Board Transfer Board
Thyristor Compensation Board Thyristor Compensation Board Thyristor Compensation Board

Thyristor Compensation

Thyristor used for quick compensation of reactive power compensation systems sudden short circuit the load and the length of stay, comes into play.

Classical methods of reactive power compensation in time, especially in a sudden start current capacitor contactors is engaged in entering and exiting the sudden circuit occurs. Perforation of the capacitor circuit to enter and exit sıklaştık sudden onset of flow occurs under the influence. This arc will cause rapid deterioration of the capacitor. This arch leads to the short life of the capacitor, forming a temporary overload on capacitors.

Thyristor speed compensation as a switching element in the system of compensation instead of the contactor used in conventional thyristor module used special compensation. Although the direct connection of capacitors using thyristors provided with the introduction of 10 ms also occurred in sudden onset flow is blocked. In this way only nominal compensation capacitors thyristor current flows from the group. It installs as a short-term problem of sudden changing method can also be compensated. In addition, the center can be done quickly with compensation compensation between 40 and 200 ms, reactive power compensation is not paid

The use of thyristors compensation system of advantages;

Heat losses are reduced, the savings from reduced losses.

Because there is no contactor maintenance costs.

Precise, fast and an accurate compensation of reactive power compensation is not paid.

It extends the life of the capacitor.

Point and the quality of products in manufacturing requiring arc increases.

Because the system is modular as desired compensation force can be increased.

Static thyristor Compensation

Tristar symbol

static compensation system used in situations where rapid changes of reactive power. Quick formation is prevented. It is a maintenance-free system. Static (thyristor switching) operation of the compensation system; Bus voltage of the capacitor voltage is switched capacitor banks at zero and the current attempts to deactivate the zero point.

Static compensation system in which a thyristor semiconductor switching elements are used. TriStar symbol is seen on the side of our way. Thyristors, power has a fast opening and closing properties when used in electronic circuits. Thyristors that are opening and closing 25,000 times per second. A semiconductor thyristor comprising four fold (P-N-P-N) gate (gate) end of the conductors can be made. Tristar compensation by firms up to 2400 volts and 3300 amperes thyristor manufacturing employees have been made. Tristar prices vary according to the value of volts and amps.

Thyristor compensation schools, municipalities, grocery stores, gas stations, hotels, mainly uses single-phase power source machine and is used in all workplaces.

benefits of static thyristor according to intended use of the compensation system;

Engaged at frequent intervals and interests, with the average time to enter and exit this circuit is 20 ms.

quickly to load changes are in response to data.

Static thyristor desired amount of compensation circuit parallel connected thyristors are made to increase the power compensation system is modular.

Because there are no maintenance costs contactor, voltage and switching currents give rise to the pits.

can not wait to get to the stage of the discharge of the capacitor.

If the desired power stage is the possibility of unlimited increase.

It is noiseless running and does not constitute arc.

More and triggering a while makes a zero crossing.

Punto et al gains in manufacturing quality value of the product should be resources.

the circuit components (capacitors, reactors) long life.

All kinds of relays, it can work with PLC or PC.

used area of ​​the static compensation system; spot welding, arc welding, presses, cranes, etc. are loads.

Differences between the contactor Compensation Thyristor

Thyristor compensation contactors has changed very fast reactive power requirements, requested the current-voltage fluctuation, the reactive power compensation system is used as the switching element. Some of the thyristor compensation contactor brand of microprocessor-based control module, the voltage of the full zero crossing switching By prevents fluctuations, whereby the CNC / PLC and also of the plant in sensitive equipment such as computers, that may result to switching reactive power compensation, eliminating the problem. Thyristor compensation contactors, spot welding machines, cranes, arc furnaces, such as reactive power requirement is fast and effective in a wide range of varying loads of reactive power compensation. Thyristor compensation contactors, has certain advantages over the electromechanical contactors.

a) contactor Compensation

a time as is necessary to keep the value of the set time of 2-8 seconds cosφ'n enters the load circuit.

To keep the limit values ​​of reagent inputs and outputs of the circuit is slow in the desired limit is not possible.

Reagents for failing to keep the required limit values ​​recognize quickly switched into appliances.

Capacitors circuit enters the contactor contacts between sparkler (arc) occurs, contact the corruption that is noisy operation and contactors. Therefore, the arc occurring in the use of capacitor contactors shorten their duration.

Inspection and maintenance are the needs.

b) Dynamic Compensation (Thyristor-Fired)

Enter the load circuit when the value of the amount cosφ'y permanent set. Processing is done in 20 ms.

reactive limits that come and go fast circuit max. It saves holding between 1% ... 5%.

Capacitors are switched to "0" is the transition point. It runs smoothly and does not spark.

Capacitors are switched to "0" capacitors for taking the transition point not wear out and life is prolonged several years.

Dynamic compensation does not require maintenance.

4000A 100 kA Dikili Tip Tip Testi (61439-1/2) Alçak Gerilim ADP Panoları Form 4B/IP55/IK10 4000A 100 kA Dikili Tip Tip Testi (61439-1/2) Alçak Gerilim ADP Panoları Form 4B/IP55/IK10 4000A 100 kA Dikili Tip Tip Testi (61439-1/2) Alçak Gerilim ADP Panoları Form 4B/IP55/IK10 4000A 100 kA Dikili Tip Tip Testi (61439-1/2) Alçak Gerilim ADP Panoları Form 4B/IP55/IK10 4000A 100 kA Dikili Tip Tip Testi (61439-1/2) Alçak Gerilim ADP Panoları Form 4B/IP55/IK10

4000 100 kA Standing Type Test (61439-1 / 2) Low Voltage Panels Form 4B ADP / IP55 / IK10
Thanks to the width of the GMS Board modular structure and product range offers solutions for all applications quickly with all kinds of switching brands

Modular, robust, flexible and aesthetic structure due to changes in the project that may occur during production or in the field is to adapt quickly and in a simple way.

The biggest feature is different from other boards is a special type of hinge bolt as the cover plate pass,

Again, thanks to the hinge cover plate without a screwdriver and wrench has a fast and simple insertion and removal feature eliminates the worry is missing bolts.

GMS Board isolators are comb bar brackets (IEC / EN 61439-2 by)

Live for metal surfaces as specified in the support section, all plastic parts of electricity arising from the effects of temperature rise and fire-resistant flame to test whether transmission has been documented in the 30s tested at 960 ° C.

general features


Forming types: up to 4b.
Icw: the main bar to short-circuit withstand current 100 kA / 1s'y up (to 4000 bars)
Ipk: the main bar to short-circuit withstand current 220 kA / 3ms'y up (to 4000 bars)
IEC 61439-1 / 2
IP 20 - IK 08 Kapısız cover plate
IP 30 - IK 08/10 Metal & Glass Doors
IP 31 - IK 08/10 Metal & Glass Doors
IP 40 - IK 08/10 Metal & Glass Doors
IP 43 - IK 08/10 Metal & Glass Doors
IP 54 - IK 08/10 Metal & Glass Doors
IP 55 - IK 08/10 Metal & Glass Doors
Board Material (IEC 61439-2) 10.2,10.2.2
Sheet metal corrosion protection
Surface, anti-corrosion coatings thermal polymerized epoxy-polyester powder paint
Carcass Frame galvanized
Carrier galvanized mounting plate
Door, side door, rear door, painted RAL7035 Cover plate
Sub base and door painted RAL7035

Recessed and Surface Mounted Type Test (61439-1/2) Low Voltage Distribution Panels Recessed and Surface Mounted Type Test (61439-1/2) Low Voltage Distribution Panels Recessed and Surface Mounted Type Test (61439-1/2) Low Voltage Distribution Panels Recessed and Surface Mounted Type Test (61439-1/2) Low Voltage Distribution Panels Recessed and Surface Mounted Type Test (61439-1/2) Low Voltage Distribution Panels

Because of GMS Dashboard modular structure and broad range of products , all applications with all kinds of brand switching solution offers a fast way

 

Because of , robust, flexible and aesthetic of structures of models , the things that may occur during production or in the field it may change quickly and simple. .

 

Unlike other boards BOLTS of the most important feature of the cover plate is cross type with special hinges ,

 

Again, because of using a hinges , screwdriver and switch cover plates capable of insertion and removal quick and simple way .

 

GMS Board comb busbar isolators supports ( IEC / EN 61439-2 according to )

 

Supplied of metal surfaces as specified in section bearings , all plastic parts that may arise from the effects of electrical and fire resistant to temperature rise of 960 ° C for 30s flame retardancy test has been documented and tested .

 

 

 

General features

 

 Forming types: up to 4b .

 Icw : 85 ka/1s main bus short circuit withstand current up to ( with bars in 4000 )

 Ipk : 188 ka/3ms main bus short circuit withstand current up to ( with bars in 4000 )

 IEC 61439-1/2

 IP 20 - IK 08 cover plate without door

 IP 30 - IK 08/10 Doors Metal & Glass

 IP 31 - IK 08/10 Doors Metal & Glass

 IP 40 - IK 08/10 Doors Metal & Glass

 IP 43 - IK 08/10 Doors Metal & Glass

 IP 54 - IK 08/10 Doors Metal & Glass

 IP 55 - IK 08/10 Doors Metal & Glass

 Board Material (IEC 61439-2 ) 10.2,10.2.2

Sheet metal corrosion protected

Surface , anti- corrosion, heat- polymerized epoxy -polyester powder coating

Carcass Galvanized Frame

Plate mounting in Galvanized chassis

Door, side cover, back cover , Cover plate painted RAL7035

Sub- base and door painted RAL7035

Legrand LV Panel Systems
Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems Legrand XL ³ 4000 LV Panel Systems

CARACTERISTIQUES

¡ IP 30 / IP 55 (avec porte et joint pour jumelage)

¡ IK 08

¡ Tenue au feu : 750‹/30 s

¡ Courant assigne de courte duree Icw : jusqufa

110 kA (avec jeu de barres 4000 A)

¡ 3 largeurs

- 475 mm (gaine a cables)

- 725 mm (24 modules par rangee)

- 975 mm (36 modules par rangee ou

24 modules par rangee + gaine a cables interne)

¡ Recoivent des appareils jusqufa 4000 A

¡ 3 types de plastrons (4 tour plombable, a vis

avec ou sans charniere, a charnieres et serrures)

¡ Choix de la repartition : standard ou optimisee

(chassis colonne XL-Part 800 et XL-Part 1600,

repartiteurs de rangee 250 A et 400 A)

¡ Formes de separation : jusqufa 4b

¡ Indice de service : jusqufa IS 333

¡ Couleur : RAL 7035

¡ Conforme a la norme CEI 60439-1

Legrand XL ³ 800 LV Panel Systems Legrand XL ³ 800 LV Panel Systems

XL³ 800 Series

 

Thanks to the broad range of products , Legrand quality

wishes freely and as simple , proven

responds with ease of application .

³ board with the new XL 400 , brings innovation to the concept of integration .

Selected panels , work habits, whatever the technical requirements of the construction site ,

XL³ 800 in ³ surely find a solution to suit your needs , you know .

 

XL³ 800  for easy and safe installation is yararlanmat from numerous practical innovations .

• Metal or insulated panels

• Wiring kit to ensure full access to the products given as

• optimized for easy application equipment

• ¼ turn lock locking metal cover plates and catchers

• the edges of the rails , mounting plates with the 10 wrench and screwdriver enough to cover plakalarınınmontaj

• 4 screw / nut easy horizontal and vertical coupling

• To ensure maximum protection during transport cardboard packaging that can be reused

 

 

General features

 

XL ³ 800 to allow proper installation of all the sights .

 IP 20 - IK 08 Kapısız cover plate

 IP 30 - IK 08 Doors Metal & Glass

 IP 40 - IK 08 Doors Metal & Glass

 IP 43 - IK 08 Doors Metal & Glass

 IP 55 - IK 08 Doors Metal & Glass

Class I and class II 

 flame retardancy : 750 ° / 5s (IEC 60695-2 )

 Short term resistance to short-circuit current : 1h until 25ka

Up to 630 devices can be mounted

 width of 3 types

 500 mm ( cable / busbar compartment )

 700 mm ( 24 modules )

 950 mm ( 36 modules 24 modules or cable / busbar compartment )

 height of 4 types

 1095 mm

 1295 mm

 1595 mm

 1995 mm

 Depth 250 mm

 Distribution selection: standard or optimized

 can be combined (left and / or right) and may donanımlandırıl cable / busbar eyes : Lexic , DPX

And distribution Cihazlr

 Ral 7035

 IEC 61439-1/2

Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems Legrand XL ³ 400 LV Panel Systems

 

XL³ 400 Series

 

Thanks to the broad range of products , Legrand quality

wishes freely and as simple , proven

responds with ease of application .

³ board with the new XL 400 , brings innovation to the concept of integration .

Selected panels , work habits, whatever the technical requirements of the construction site ,

XL 400 in ³ surely find a solution to suit your needs , you know .

 

³ 400 XL for easy and safe installation is yararlanmat from numerous practical innovations .

• Metal or insulated panels

• Wiring kit to ensure full access to the products given as

• optimized for easy application equipment

• ¼ turn lock locking metal cover plates and catchers

• the edges of the rails , mounting plates with the 10 wrench and screwdriver enough to cover plakalarınınmontaj

• 4 screw / nut easy horizontal and vertical coupling

• To ensure maximum protection during transport cardboard packaging that can be reused

 

 

General features

 

XL ³ 400 to allow proper installation of all the sights .

 IP 20 - IK 08 Kapısız cover plate

 IP 30 - IK 08 Doors Metal & Glass

 IP 40 - IK 08 Doors Metal & Glass

 IP 43 - IK 08 Doors Metal & Glass

 IP 55 - IK 08 Doors Metal & Glass

Class I and class II 

 flame retardancy : 750 ° / 5s (IEC 60695-2 )

 Short term resistance to short-circuit current : 1h until 25ka

 Place 24 modules per

Up to 400 devices can be mounted 

 Distribution selection: standard or optimized

 can be combined (left and / or right) and may donanımlandırıl cable / busbar eyes : Lexic , DPX

And distribution Cihazlr

 Ral 7035

 IEC 61439-1/2

 

IP65 Weather Proof of the conduit box Plexo³

Self-extinguishing: Hot wire test 350 ° C according to EN-60439-3 standard conduit box of damp places: IP 65. IK 09 Class II Coffret door convertible and completely the opposite direction. Two or more order, can be equipped with a removable chassis and cover plates and two-position modular products for DPX rail rails between 150 mm plain or perforated mounting plate for mounting non-modular products. Lockable door handle, sealable container


We have a wide assortment of boxed ...

11 different sizes boxed

Up to 8 modules of 2 modules

12 modules - up to 3 1 ordinary order

18 modules - up to 4 1 ordinary order


All kinds fit your configuration

Plexo3 are boxed into:

DPX 2-position switch mounted on rails

Osmosis Ø221 mm control buttons can be placed flat cover plate for mounting.

Security Guarantee:

Seals can be placed between the cover and the cover plate or cover and boxed rear.

Opening handle key lock can be fitted.

Allowing direct connection with termination plugs

ISO directly by the cable glands. It can be fixed and removed without hand tools. The cable is connected when the IP 65, IK has 09 guarantee. According to Standard cable gland cable has more capacity. Cable glands keeps in a safe manner.

Legrand Coffret are Practibox Legrand Coffret are Practibox Legrand Coffret are Practibox

Legrand Practibox conduit box is seamlessly integrated into your stylish and aesthetic appearance of work and living space.
IEC 439 in accordance with the standards developed by Legrand boxed Practibox they offer an effective protection. Quick installation and easy to use facility that blends perfectly with your project Practibox Legrand, Halogen Free feature, which fulfills the required specifications. 6, 8, 12, (2 × 12) 24 (3 × 12) with 36 module options Practibox meets the market's needs.

  Practibox flush boxed sets are a regular appearance in less module system with a half-module each piece in removable eight and while the possibility to expand the system by adding modules, connections through the empty spaces left behind the rail makes it possible to more easily made.

 

XL³ 160 LV Panel System

XL³ metal 160 series is available in 3 different options, including plastic and boxed flush. XL³ 160 series is based on 24-module options 6 2 ordinary as far completely modular, alarm boxed in accordance with the type of test standards. It offers optimized size distribution for up to 160. width up to 1050 mm height in the conduit box solution offering from 575 mm to 450 mm, and the depth is 147 mm (door). XL³ 160 series of curved metal doors, curved glass doors, flat metal doors, there are four different door options, including flat glass door. XL³ 160 boxed sets it has an excellent aesthetic appearance thanks to four different door options.


FEATURES

• Compliance with the IEC 61439-1-2 standard

• IEC 60695-2-1-750 ° C / 5s by heat resistance

• Ipk resistance to short-circuit 35 kA

• Doors IP 30, IP 40 and IP 43 sealing doors and

• Door HR 07, HR 08

• Compliance with the installation of up to 160 devices

 • RAL 7035 color, paint epoksipolyest is 50/70 μ

Legrand XL³ 6300 LV Panel System

XL³ 6300 series main distribution boards has been specially designed to distribute your energy at high power in your business. XL³ 6300 and 6300 series boards 4b until all forms completely modular type to design freely, internal or external cable can be completed type-tested with the eyes of the bar are the main distribution board. 1425 mm in width to allow you to perform your preferred board layout easily and are manufactured in three different depths. It can be done back to back and side to side or combining XL3 4000 series is designed to work with the board in accordance with the merge. Strong structure and practice is the number one partner for your power distribution with ease.

FEATURES

• Compliance with the IEC 61439-1-2 standard

• Rated operating voltage (A): 415 V

• Rated isolation voltage (U): 690 V

 • Impulse voltage (Uimp): 8 kV

• Rated Frequency (Hz): 50 -60 Hz

• Rated short-term current (Icw) 100 kA

• Rated short-circuit current (Icc) 100 kA (at 415 V)



Beylikdüzü O.S.B. Bakır Ve Pirinç San. Sit. Leylak Cad. No:4 Beylikdüzü / İSTANBUL
+90 212 875 73 15 pbx +90 212 876 73 14
info@gmspano.com